Strona 1 - EX8654, EX8658

SUPERTRAK EX4650, EX8650,EX8654, EX8658USER MANUALVersion 1.1

Strona 2 - Recommendations

SuperTrak EX Series User ManualxChapter 5: Management with WebPAM PRO, cont.Managing Disk Arrays, cont.Creating a Disk Array – Express Configuration

Strona 3

SuperTrak EX Series User Manual88Figure 3. WebPAM PRO Tree View The Administrative Tools section is different for the Administrator and Super Users th

Strona 4

Chapter 5: Management with WebPAM PRO89Choosing a Display LanguageWebPAM PRO displays in the following languages:To change the display language:1. Cli

Strona 5

SuperTrak EX Series User Manual90You can also view events by clicking the Subsystems icon in Tree View, then clicking the Event tab in Management Vi

Strona 6

Chapter 5: Management with WebPAM PRO91 Figure 4. The Storage Network appears in Tree ViewTo view the Storage Network, click Show Storage Network in t

Strona 7

SuperTrak EX Series User Manual92Managing UsersUser Management includes all functions dealing with user accounts. Functions include:• Viewing User Inf

Strona 8

Chapter 5: Management with WebPAM PRO93You can also set user privilege under Subsystem/Host Management. See “Setting User Privilege” on page 97 and “S

Strona 9

SuperTrak EX Series User Manual948. Click the Submit button. Creating a UserTo create a user:1. Log into WebPAM PRO as the Administrator or a Super Us

Strona 10

Chapter 5: Management with WebPAM PRO952. Click the Administrative Tools icon. 3. Click the User Management icon.4. Click the Delete tab in Manage

Strona 11 - Contents

SuperTrak EX Series User Manual96Working with Subsystem/Host ManagementSubsystem/Host Management includes the following functions:• Viewing Subsystem/

Strona 12

Chapter 5: Management with WebPAM PRO975. Do one of the following actions:• To create an in-band connection: Type the Host PC’s IP address into the ad

Strona 13 - Chapter 1: Introduction

ContentsxiChapter 6: Technology Background . . . . . . . . . . . . . . . . . . . . . . . .155Introduction to RAID . . . . . . . . . . . . . . . .

Strona 14 - Product Overview

SuperTrak EX Series User Manual983. click the IP address link of the Subsystem or Host you want to access.4. Beside the name of the user whose privile

Strona 15 - Browser Support

Chapter 5: Management with WebPAM PRO99Managing Software ServicesSoftware Services include the following functions:• Viewing Service Status (page 99)•

Strona 16 - Key Features and Benefits

SuperTrak EX Series User Manual100The range is 1 to 1440 minutes. 15 minutes is the default.Session Time Out refers to the amount of time the connecti

Strona 17

Chapter 5: Management with WebPAM PRO101Setting up Extended SMTPTo make Extended SMTP settings:1. Click the Administrative Tools icon in Tree View.2

Strona 18 - Specifications

SuperTrak EX Series User Manual102Changing CIM Client SettingsThe CIM client is part of the WebPAM PRO Utility Server. The Utility Server can be insta

Strona 19 - Chapter 2: Installation

Chapter 5: Management with WebPAM PRO103Managing the HostThe Host is designated by its IP address:127.0.0.1. Host functions include:• Viewing Host Inf

Strona 20 - Installing the SuperTrak Card

SuperTrak EX Series User Manual104Managing the SubsystemSubsystem functions include:• Viewing Subsystem Information (page 104)• Clearing Statistical D

Strona 21

Chapter 5: Management with WebPAM PRO105Clearing Statistical DataUse this function to clear the statistical data registers for the controller, physica

Strona 22

SuperTrak EX Series User Manual1064. Navigate to the directory where you saved the upgrade file, then click the upgrade file, and click the Open butto

Strona 23

Chapter 5: Management with WebPAM PRO107• Fatal – Non-Recoverable error or failure has occurred Saving the Runtime Event LogThis function saves a copy

Strona 24

SuperTrak EX Series User ManualxiiChapter 6: Technology Background, cont.Predictive Data Migration (PDM) . . . . . . . . . . . . . . . . . . . . . .

Strona 25 - Scenario 5: SAS Expanders

SuperTrak EX Series User Manual108Severity DefinitionsEach event is marked with a level of severity.• Information – Information only, no action is req

Strona 26 - Choosing the Physical Drives

Chapter 5: Management with WebPAM PRO109Viewing Current Background ActivitiesTo view the current background activities:1. Click the Subsystem icon i

Strona 27

SuperTrak EX Series User Manual1104. Highlight the following PDM trigger settings and type a value into the corresponding field:• Reassigned Block Thr

Strona 28

Chapter 5: Management with WebPAM PRO1113. In the next screen, click the Start button.Running PDMPredictive Data Migration (PDM) migrates data from th

Strona 29

SuperTrak EX Series User Manual1125. Click the option button for the Recurrence Pattern you want: •Daily •Weekly •Monthly6. Click the Next button.7. F

Strona 30

Chapter 5: Management with WebPAM PRO11310. For Redundancy Check only:• Choose the Auto Fix option. This feature attempts to repair the problem when i

Strona 31

SuperTrak EX Series User Manual114• Physical Drive List – Device number, model, type, capacity, location, operational status, and configuration• Disk

Strona 32 - Installing WebPAM PRO

Chapter 5: Management with WebPAM PRO115Managing the ControllerThe RAID controller is the heart of the RAID storage system. Management of Controllers

Strona 33 - Internet Browser

SuperTrak EX Series User Manual116Controller information includes:• Controller ID (1 or 2)• Alias, if assigned*• Vendor• Model• Operational Status•Pow

Strona 34

Chapter 5: Management with WebPAM PRO117Controller information, continued:• SMART Polling Interval*• Write Back Cache Flush Interval*• Write Through

Strona 35

1Chapter 1: Introduction• About This Manual, below• Product Overview (page 2)• WebPAM PRO Management Software (page 3)Thank you for purchasing one of

Strona 36

SuperTrak EX Series User Manual118• Choose a coercion method from the Coercion Method dropdown menu. The choices are:•GBTruncate• 10GBTruncate• GRPRou

Strona 37

Chapter 5: Management with WebPAM PRO1193. Click the Controller icon. 4. Click the Battery tab in Management View. In normal operation, the operatio

Strona 38

SuperTrak EX Series User Manual1204. Click the Buzzer tab in Management View.5. Click the Sound button.The buzzer sounds a continuous tone.6. Click th

Strona 39

Chapter 5: Management with WebPAM PRO121Managing EnclosuresThis function of WebPAM PRO does not apply to the SuperTrak RAID controller card installed

Strona 40

SuperTrak EX Series User Manual122Managing Physical DrivesManaging Physical Drives deals with the physical disk drives under the SuperTrak RAID contro

Strona 41

Chapter 5: Management with WebPAM PRO123To locate a physical drive in the enclosure, click the Locate PDx button. The LED for the carrier holding the

Strona 42

SuperTrak EX Series User Manual124The functions you enable here depend on whether the physical drives support those functions. See “Viewing Physical D

Strona 43

Chapter 5: Management with WebPAM PRO125Making Physical Drive SettingsThe only individual physical drive setting is an alias. An alias is optional. To

Strona 44

SuperTrak EX Series User Manual126Clearing Stale and PFA ConditionsThe Clear tab only appears when one or both conditions are present.• Stale – The ph

Strona 45

Chapter 5: Management with WebPAM PRO127Managing Disk ArraysDisk Array Management includes the following functions:• Viewing Disk Arrays (page 127)• L

Strona 46

SuperTrak EX Series User Manual2Product OverviewSuperTrak EX4650, EX8650, EX8654, and EX8658 are SAS and SATA RAID Controller cards. When used with We

Strona 47

SuperTrak EX Series User Manual128Promise EnclosuresTo locate a disk array in a VTrak JBOD enclosure, click the Locate DAx button. The disk status LED

Strona 48

Chapter 5: Management with WebPAM PRO129Creating a Disk Array – Automatic ConfigurationThe Disk Array – Automatic Configuration option enables you to

Strona 49 - Logging into WebPAM PRO

SuperTrak EX Series User Manual130Creating a Disk Array – Express ConfigurationThe Disk Array – Express Configuration option enables you to choose the

Strona 50 - Login Screen

Chapter 5: Management with WebPAM PRO131• Logical Drives – The slot number of the logical drive(s), their RAID level, capacity, and stripe size • Spar

Strona 51 - Setting up WebPAM PRO

SuperTrak EX Series User Manual132Creating a Disk Array – Advanced ConfigurationThe Disk Array – Advanced Configuration option enables you to directly

Strona 52

Chapter 5: Management with WebPAM PRO133This value will be the data capacity of the first logical drive in your new disk array. If you specify less th

Strona 53 - Chapter 3: Installing Drivers

SuperTrak EX Series User Manual134Deleting a Disk ArrayThe Disk Arrays–Delete tab enables you to delete existing disk arrays.To delete a disk array:1.

Strona 54 - Driver Diskette for Linux

Chapter 5: Management with WebPAM PRO135available. However, the logical drive has lost redundancy (fault tolerance). You must determine the cause of t

Strona 55 - Windows Vista

SuperTrak EX Series User Manual136Maximum of 32 characters. Use letters, numbers, one space between words, and underscore. An alias is optional.6. To

Strona 56 - Existing System

Chapter 5: Management with WebPAM PRO137The choices are Read Cache, Read Ahead, and No Cache. Read Ahead is the default. See “Choosing Cache Policy” o

Strona 57 - Windows Server 2003

Chapter 1: Introduction3WebPAM PRO Management SoftwareThe Web-Based Promise Array Management—Professional (WebPAM PRO) software offers local and remot

Strona 58

SuperTrak EX Series User Manual138In the confirmation box, type the word confirm in the field provided. 7. Click the OK button. The chosen logical dis

Strona 59 - Windows XP

Chapter 5: Management with WebPAM PRO139To set Migration priority, see “Making Background Activity Settings” on page 109.Rebuilding a Disk ArrayWhen y

Strona 60

SuperTrak EX Series User Manual140Running Media Patrol on a Disk ArrayMedia Patrol checks the magnetic media on physical drives. When it finds the spe

Strona 61 - Windows 2000

Chapter 5: Management with WebPAM PRO141Transitioning a Disk ArrayTransition is the process of replacing a revertible spare drive that is currently pa

Strona 62

SuperTrak EX Series User Manual1428. After the Transition is complete, move the physical drives comprising the disk array to their new locations. 9. C

Strona 63 - New OS Installation

Chapter 5: Management with WebPAM PRO143Managing Logical DrivesLogical drives are made from disk arrays. In the Tree, you can see a graphic representa

Strona 64 - SuSE Linux Enterprise 10.1

SuperTrak EX Series User Manual144function and your data is available. However, access will be slower due to the rebuilding operation. To create a log

Strona 65 - SuperTrak BIOS

Chapter 5: Management with WebPAM PRO1455. Click the Logical Drive icon. To specify an Alias or set the Read and Write Policies, click the Settings

Strona 66

SuperTrak EX Series User Manual146Maximum of 32 characters. Use letters, numbers, one space between words, and underscore. An alias is optional.8. Fro

Strona 67

Chapter 5: Management with WebPAM PRO147To set Initialization priority, see “Making Background Activity Settings” on page 109.You can also start Initi

Strona 68 - Main Menu

SuperTrak EX Series User Manual4If you do not have one of the above browsers, install the browser first and make it the default browser. Then install

Strona 69 - Controller Selection

SuperTrak EX Series User Manual1483. Click the Disk Array icon. 4. Click the Logical Drives icon5. Click the Logical Drive icon. 6. Click the Ch

Strona 70 - Controller Information

Chapter 5: Management with WebPAM PRO149Managing Spare DrivesWhen a physical drive in a disk array fails and a spare drive of adequate capacity is ava

Strona 71 - Physical Drive Management

SuperTrak EX Series User Manual150Creating a Spare Drive To create a spare drive:1. Click the Subsystem icon in Tree View. 2. Click the Spare Drives

Strona 72

Chapter 5: Management with WebPAM PRO151Deleting Spare DriveTo delete a spare drive:1. Click the Subsystem icon in Tree View. 2. Click the Spare Dri

Strona 73 - Disk Array Management

SuperTrak EX Series User Manual152Running Spare CheckSpare Check verifies the operational status of your spare drives. You can also schedule a Spare C

Strona 74

Chapter 5: Management with WebPAM PRO153Working with the Logical Drive SummaryThe Logical Drive Summary displays a list of all logical drives under th

Strona 75 - Changing Disk Array Settings

SuperTrak EX Series User Manual154Viewing Individual Logical Drive Information1. Click the Subsystem icon in Tree View. 2. Click the Logical Drive S

Strona 76 - Logical Drive Management

155Chapter 6: Technology Background• Introduction to RAID (below)• Choosing a RAID Level (page 168)• Choosing Stripe Block Size (page 172)• Choosing S

Strona 77

SuperTrak EX Series User Manual156RAID 0 – StripeWhen a logical drive is striped, the read and write blocks of data are interleaved between the sector

Strona 78

Chapter 6: Technology Background157RAID 1 – MirrorWhen a logical drive is mirrored, identical data is written to a pair of physical drives, while read

Strona 79

Chapter 1: Introduction5Displays status and error checking messages during bootupNotifies user of possible errors and allows for recovery of mirrored

Strona 80

SuperTrak EX Series User Manual158RAID 1E – Enhanced MirrorRAID 1E offers the security of mirrored data provided by RAID 1 plus the added capacity of

Strona 81 - Rebuilding the Logical Drive

Chapter 6: Technology Background159RAID 5 – Block Striping with Distributed ParityRAID 5 organizes block data and parity data across the physical driv

Strona 82

SuperTrak EX Series User Manual160RAID 6 – Block and Double Parity StripeRAID level 6 stores dual parity data is rotated across the physical drives al

Strona 83 - RAID 1, 5, 6, 10, 50 and 60

Chapter 6: Technology Background161RAID 10 – Mirror / StripeMirror/Stripe combines both of the RAID 0 and RAID 1 logical drive types. RAID 10 is simil

Strona 84

SuperTrak EX Series User Manual162RAID 50 – Striped Distributed ParityRAID 50 combines both RAID 5 and RAID 0 features. Data is striped across physica

Strona 85 - Spare Drive Management

Chapter 6: Technology Background163RAID 50 AxlesWhen you create a RAID 50, you must specify the number of axles. An axle refers to a single RAID 5 log

Strona 86 - Changing Spare Drive Settings

SuperTrak EX Series User Manual16415 2 7,835,5,54 3,4,4,45 3,3,3,3,316 2 8,835,5,64 4,4,4,45 3,3,3,3,4RAID 50 Logical DriveNo. of Drives No. of Axles

Strona 87 - Deleting a Spare Drive

Chapter 6: Technology Background165RAID 60 – Striping of Double ParityRAID 60 combines both RAID 6 and RAID 0 features. Data is striped across disks a

Strona 88 - Background Activity

SuperTrak EX Series User Manual166RAID 60 AxlesWhen you create a RAID 60, you must specify the number of axles. An axle refers to a single RAID 6 logi

Strona 89 - Event Log

Chapter 6: Technology Background16718 2 9,936,6,64 4,4,5,519 2 9,1036,6,74 4,5,5,520 2 10,1036,7,74 5,5,5,55 4,4,4,4,4RAID 60 Logical DriveNo. of Driv

Strona 90 - Clearing the Event Logs

SuperTrak EX Series User Manual6Specifications• Low-profile printed circuit board• PCI-Express x8 Slot• Controller card dimensions (HWD):2.69 x 6.63 x

Strona 91 - Time Sync

SuperTrak EX Series User Manual168Choosing a RAID LevelThere are several issues to consider when choosing the RAID Level for your logical drive. The f

Strona 92 - Miscellaneous

Chapter 6: Technology Background169RAID 1ERecommended Applications for RAID 1E• Imaging applications • Database servers • General fileserverRAID 5Reco

Strona 93

SuperTrak EX Series User Manual170RAID 6Recommended applications for RAID 6:• Accounting/Financial• Database servers• Any application requiring very h

Strona 94

Chapter 6: Technology Background171RAID 50Recommended applications for RAID 50:• File and Application Servers• Transaction Processing• Office applicat

Strona 95

SuperTrak EX Series User Manual172Choosing Stripe Block SizeYou set the stripe block size, also called block size, when you create a logical drive. Wi

Strona 96 - Logging in over the Network

Chapter 6: Technology Background173• Linux operating systems with the 2.6 kernel support 64-bit LBA. For these OSes, always choose the default 512 B s

Strona 97

SuperTrak EX Series User Manual174Read Cache Policy• Read Cache – The read cache is enabled. • Read Ahead – The read cache and the read-ahead feature

Strona 98 - Accessing the Interface

Chapter 6: Technology Background175Without Capacity Coercion, the controller will not permit the use of a replacement physical drive that is slightly

Strona 99 - Using Tree View

SuperTrak EX Series User Manual176Whenever possible, having a hot spare drive in your RAID system is good protection against physical drive failure.Pa

Strona 100 - Using Management View

Chapter 6: Technology Background177RAID 0A RAID 0 source logical drive can migrate to the following target logical drives:Target RequirementsRAID 0 Ad

Strona 101 - Viewing the Event Frame

7Chapter 2: Installation• Unpacking the SuperTrak, below• Installing the SuperTrak Card (page 8)• Choosing the Physical Drives (page 14)• Creating a L

Strona 102 - Viewing the Storage Network

SuperTrak EX Series User Manual178RAID 1A RAID 1 Source logical drive can migrate to the following Target logical drives:RAID 1EA RAID 1E Source logic

Strona 103 - Logging out of WebPAM PRO

Chapter 6: Technology Background179RAID 5A RAID 5 Source logical drive can migrate to the following Target logical drives:RAID 6A RAID 6 Source logica

Strona 104 - Managing Users

SuperTrak EX Series User Manual180RAID 10A RAID 10 Source logical drive can migrate to the following Target logical drives:Target RequirementsRAID 0 N

Strona 105 - Changing Your Own Password

Chapter 6: Technology Background181RAID 50A RAID 50 Source logical drive can migrate to the following Target logical drives:RAID 60A RAID 60 Source lo

Strona 106 - Deleting a User

SuperTrak EX Series User Manual182Ranges of Disk Array ExpansionThe Windows 2000 and Windows XP (32-bit) operating systems support a 10-byte LBA forma

Strona 107

Chapter 6: Technology Background183At this point, you have the choice of:• Format the unpartitioned/unformatted capacity as a second logical drive• De

Strona 108 - Adding a Subsystem or Host

SuperTrak EX Series User Manual184Media PatrolMedia Patrol is a routine maintenance procedure that checks the magnetic media on each physical drive. M

Strona 109 - Setting User Privilege

Chapter 6: Technology Background185the bad sector remapping table, which has a capacity of 512 reassigned blocks and 1024 error blocks.When the table

Strona 110

SuperTrak EX Series User Manual186• The physical drive in channel 4 is a revertible spare drive.The physical drive in channel 2 fails. The disk array

Strona 111 - Managing Software Services

Chapter 6: Technology Background187Automatic TransitionAt this juncture, you would replace the failed drive in channel 2 with a new drive of the same

Strona 112 - Setting up Email Service

SuperTrak EX Series User ManualiiCopyright© 2008 Promise Technology, Inc. All Rights Reserved.Copyright by Promise Technology, Inc. (Promise Technolog

Strona 113 - Sending A Test Email Message

SuperTrak EX Series User Manual8Installing the SuperTrak CardThe SuperTrak EX Controller card fits into any available 3.3-volt PCI-Express x8 slot. Yo

Strona 114 - Changing CIM Server Settings

SuperTrak EX Series User Manual188The physical drive in channel 2 fails. The disk array becomes degraded and its logical drives go critical. The Super

Strona 115 - Managing the Host

Chapter 6: Technology Background189Critical & Offline Logical DrivesA fault-tolerant logical drive—RAID 1, 1E, 5, 6, 10, 50, or 60—goes critical w

Strona 116 - Managing the Subsystem

SuperTrak EX Series User Manual190• Sends email messages, per your configuration• Displays popup messages, per your configuration (below)• Keeps a rec

Strona 117 - Updating the Firmware

Chapter 6: Technology Background191With a Hot Spare DriveWhen a physical drive in a disk array fails and a spare drive of adequate capacity is availab

Strona 118 - Viewing the Runtime Event Log

SuperTrak EX Series User Manual192After a successful rebuild: • The alarm is silent • The logical drive’s Operational Status as OK • The rebuilt physi

Strona 119 - Viewing the NVRAM Event Log

193Chapter 7: Support• Frequently Asked Questions (below)• Contacting Technical Support (page 197)• Limited Warranty (page 199)• Returning the Product

Strona 120 - Clearing the NVRAM Event Log

SuperTrak EX Series User Manual194Can I use ATAPI devices on the SuperTrak EX Series? No. The SuperTrak EX Series Controller does not support ATAPI de

Strona 121

Chapter 7: Support195If I have a problem with one of the drives on the SuperTrak EX Series, how can I low-level format it to correct the problem? Do N

Strona 122 - Running Media Patrol

SuperTrak EX Series User Manual196Installation Issues (Capacity, Booting)How can I change the system boot sequence in order to boot from the SuperTrak

Strona 123 - Scheduling an Activity

Chapter 7: Support197Why can’t I run WebPAM PRO in Konqueror? The Konqueror browser (Linux) does not support WebPAM PRO. Install a Netscape Navigator

Strona 124

Chapter 2: Installation9 Figure 1. SuperTrak EX4650 card Figure 2. SuperTrak EX8650 cardBBU module connectorCPU Fan connectorI2C/SMBus connectorActivi

Strona 125 - Viewing System Configuration

SuperTrak EX Series User Manual198The NetherlandsGermanyItalyE-mail Support e-Support On-LineFax Support +31 (0) 40 256 9463 Attn: Technical SupportPh

Strona 126

Chapter 7: Support199Taiwan China Limited WarrantyPromise Technology, Inc. (“Promise”) warrants that for three (3) years from the time of the delivery

Strona 127 - Managing the Controller

SuperTrak EX Series User Manual200This warranty shall not apply to defects resulting from:a) improper or inadequate maintenance, or unauthorized modif

Strona 128

Chapter 7: Support201Some states do not allow the exclusion or limitation of incidental or consequential damages for consumer products, so the above l

Strona 129 - Making Controller Settings

SuperTrak EX Series User Manual202Return ONLY the specific product covered by the warranty (do not ship cables, manuals, diskettes, etc.), with a copy

Strona 130 - Viewing Battery Information

203Appendix A: Partition and FormatIn order for your operating system to recognize and work with the physical drives attached to your SuperTrak EX Con

Strona 131 - Testing the Buzzer

SuperTrak EX Series User Manual2043. Click the Next button to start the Wizard.4. In the following windows, choose Disk 1 to Initialize. Do not choose

Strona 132 - Viewing Buzzer Information

Appendix A: Partition and Format2056. Click the Next button to start the wizard.7. In the following windows, do the following actions. Click Next to m

Strona 133 - Managing Enclosures

SuperTrak EX Series User Manual206When formatting is complete, your logical disk will appear as a hard drive in the Disk Management window (above) and

Strona 134 - Managing Physical Drives

207Appendix B: Upgrades• Updating SuperTrak BIOS and Firmware (page 207)• Updating WebPAM PRO (page 208)Updating SuperTrak BIOS and FirmwareFollow thi

Strona 135 - Promise Enclosures

SuperTrak EX Series User Manual10 Figure 3. SuperTrak EX8654 card Figure 4. SuperTrak EX8658 card6. Attach the other end of the SAS multi-lane cable t

Strona 136 - Adjustable Items

SuperTrak EX Series User Manual208Updating WebPAM PROFollow this procedure to upgrade the WebPAM PRO Software on your PC or server.Downloading the Web

Strona 137

209Appendix C: Battery Backup UnitThe Battery Backup Unit (BBU) maintains power to the cache on the SuperTrak EX Controller card, when a power failure

Strona 138

SuperTrak EX Series User Manual210Installing the BBU To install the BBU onto your SuperTrak EX Controller card in the Host PC:1. Power down your syste

Strona 139 - Managing Disk Arrays

Appendix C: Battery Backup Unit211 Figure 2. BBU module connectors on EX4650. Other models are similar 8. From the opposite side of the SuperTrak EX C

Strona 140 - Creating a Disk Array

SuperTrak EX Series User Manual21210. Replace the screw holding the SuperTrak EX Controller card to the system case.11. Attach the SAS multi-lane cabl

Strona 141

213Appendix D: LED Backplane ConnectionsTo set up LED configuration for your enclosure or PC, make your backplane connections as shown below. You can

Strona 142

SuperTrak EX Series User Manual214 Figure 2. SuperTrak fault and activity LED connectionsFor status and behavior information, see the table on the fol

Strona 143

Appendix D: LED Backplane Connections215To set up your system for direct (fault and activity) LEDs, you must know how the SuperTrak’s firmware status

Strona 144

SuperTrak EX Series User Manual216

Strona 145

217IndexNumerics10GBTruncate 1742 TB limitation 173AAbout This Manual 1addhost 96subsystem 96Agent, WebPAM PRO 20, 97, 102aliascontroller 117disk arra

Strona 146 - Deleting a Disk Array

Chapter 2: Installation117. Optional. Repeat steps 5 and 6 for the second SAS port on the SuperTrak EX8650, EX8654, or EX8658 card.8. Optional. Attach

Strona 147 - Making Disk Array Settings

SuperTrak EX Series User Manual218Ddedicated spare drive 175degraded logical drive 143deletedisk array 63, 134Event Frame 90host 97logical drive 67, 1

Strona 148 - Creating a Logical Drive

Index219Extended SMTP 101Ffailed physical drive 189FAQsinstallation 196physical drives 194post installation 196pre-installation 193find failed physica

Strona 149 - Deleting a Logical Drive

SuperTrak EX Series User Manual220Linuxinstalling drivers 51, 52installing WebPAM PRO 29listdisk arrays 61logical drives 64physical drives 59, 122sche

Strona 150 - Migrating a Disk Array

Index221overview of SuperTrak 2Ppartition logical drive 176, 203passwordchange 93WebPAM PRO 38, 85PCI-Express slot 8, 210PDMand Media Patrol 184define

Strona 151 - Rebuilding a Disk Array

SuperTrak EX Series User Manual222Read Check Table 148reassigned block threshold setting 110rebuilddisk array 139logical drive 69rebuilding a disk arr

Strona 152 - Running PDM on a Disk Array

Index223spare drivecapacity 69, 150create 73, 150dedicated to array 74, 150dedicated to disk arrays 149defined 175delete 75, 151information 73list 73,

Strona 153 - Transitioning a Disk Array

SuperTrak EX Series User Manual224Time Sync 79Tomcat server 100Transitionautomatic 187defined 185disk array 141manual 187settings 109transport, prepar

Strona 154

Index225WebPAM PRO, cont.event frame refresh 101extended SMTP 101External SSL Security option 26, 34firmware update 105first-time setup 39Header 87hos

Strona 155 - Managing Logical Drives

SuperTrak EX Series User Manual226Windowsinstalling drivers 43–50installing WebPAM PRO 22write cache policydefined 174logical drive 65, 67, 133, 137Wr

Strona 156 - Locating a Logical Drive

SuperTrak EX Series User Manual12Connecting SuperTrak to a VTrak JBOD EnclosureIf you are connecting the SuperTrak card to a single VTrak JBOD enclosu

Strona 157 - Logical Drive Synchronization

Chapter 2: Installation13The SuperTrak EX8650, EX8654, and EX8658 cards are designed to manage up to 16 enclosures and up to 256 SAS or SATA disk driv

Strona 158 - Initializing a Logical Drive

SuperTrak EX Series User Manual14In WebPAM PRO, the first Expander appears as Enclosure 2. The drives are numbered 1 to 128. The second Expander appea

Strona 159 - Running Redundancy Check

Chapter 2: Installation15Creating a Logical DriveYou can use the SuperBuild™ Configuration Utility to create a logical drive with the attached physica

Strona 160

SuperTrak EX Series User Manual163. Press the arrow keys to highlight Disk Array Management and press Enter.The Disk Array Management screen appears.4

Strona 161 - Managing Spare Drives

Chapter 2: Installation177. Highlight Return to Previous Menu and press Enter.The Main Menu appears.8. Highlight Logical Drive Management and press En

Strona 162 - Creating a Spare Drive

NoticesiiiRadio Frequency Interference StatementThis equipment has been tested and found to comply with the limits for a Class B digital device, pursu

Strona 163 - Making Spare Drive Settings

SuperTrak EX Series User Manual1811. Highlight Next Step and press Enter.The Create Logical Drive Step 2/2 screen appears.12. To change the RAID Level

Strona 164 - Running Spare Check

Chapter 2: Installation1918. To change the Read Cache Policy, highlight Read Cache Policy and press Enter.Highlight your choice of None, Read Cache, o

Strona 165

SuperTrak EX Series User Manual20Installing WebPAM PROWeb-Based Promise Array Management—Professional (WebPAM PRO) software provides a browser-based g

Strona 166

Chapter 2: Installation21• Red Hat Enterprise Linux 4.4, 4.5, 5.0, 5.1• SuSE 10.1, 10.2; SLES 10, 10 SP1• Miracle Linux 4 SP2• Fedora Core 6, 7• Asian

Strona 167 - Introduction to RAID

SuperTrak EX Series User Manual22Go to one of the following procedures:• “Installing WebPAM PRO onto a Windows PC or Server” on page 22.• “Installing

Strona 168 - RAID 0 – Stripe

Chapter 2: Installation236. In the License Agreement dialog box, choose the I accept... option, then click the Next button.Figure 10.License Agreement

Strona 169 - RAID 1 – Mirror

SuperTrak EX Series User Manual247. In the Setup Type dialog box, choose the option you prefer:• Typical – Better for most applications• Custom – For

Strona 170 - RAID 1E – Enhanced Mirror

Chapter 2: Installation258. In the Choose Destination Location dialog box, you can:• Accept the default installation folder (recommended)• Specify a d

Strona 171

SuperTrak EX Series User Manual269. In the SSL Security Options dialog box, check the box to select SSL security.External SSL Security – Applies secur

Strona 172

Chapter 2: Installation2710. In the Ready to Install dialog box, click the Install button to continue.Figure 14.Ready to Install dialog box

Strona 173 - RAID 10 – Mirror / Stripe

SuperTrak EX Series User Manualiv

Strona 174

SuperTrak EX Series User Manual2811. In the Install Complete dialog box, click the Finish button to exit the installer.Figure 15.Install Complete dial

Strona 175 - RAID 50 Axles

Chapter 2: Installation29Installing WebPAM PRO onto a Linux PC or ServerIf you have a previous version of WebPAM PRO installed on your PC or server, r

Strona 176

SuperTrak EX Series User Manual306. In the License Agreement dialog box, choose the I accept... option, then click the Next button.Figure 17.License A

Strona 177

Chapter 2: Installation317. In the Choose Product Install dialog box, choose the option you prefer:• Typical – Better for most applications• Custom –

Strona 178 - RAID 60 Axles

SuperTrak EX Series User Manual328. When the Choose Install Folder dialog box appears, you can:• Accept the default installation folder (recommended)•

Strona 179

Chapter 2: Installation339. In the WebPAM PRO Agent Configuration dialog box, click the Next button to continue.Figure 20.WebPAM PRO Agent Configurati

Strona 180 - Choosing a RAID Level

SuperTrak EX Series User Manual3410. In the SSL Security Options dialog box, check the box to select SSL security.External SSL Security – Applies secu

Strona 181

Chapter 2: Installation3511. In the WebPAM PRO Utility Server Configuration dialog box, click the Install button to continue.Figure 22.WebPAM PRO Util

Strona 182

SuperTrak EX Series User Manual3612. In the Register On-line dialog box, click the Done button to exit the installerFigure 23.Register On-line dialog

Strona 183

Chapter 2: Installation37Logging into WebPAM PROYou can log into WebPAM PRO in either of two ways:• Logging in at the Host PC (page 37)• Logging in ov

Strona 184 - Choosing Sector Size

vContentsChapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1About This Manual . . . . . . . . . . . .

Strona 185 - Choosing Cache Policy

SuperTrak EX Series User Manual38Together, your entry looks like this:https://192.168.10.228:8443/promiseLogin ScreenWhen the opening screen appears:1

Strona 186 - Capacity Coercion

Chapter 2: Installation39Setting up WebPAM PROThe first time you use WebPAM PRO, you must add the Host PC so that WebPAM PRO will recognize it. You on

Strona 187 - Hot Spare Drive(s)

SuperTrak EX Series User Manual40Figure 26.Add Subsystem/Host tab4. Click the Submit button.The newly added host appears in the Tree, on the left side

Strona 188 - RAID Level Migration

41Chapter 3: Installing Drivers• Driver Diskette for Windows (page 42)• USB Memory Stick for Windows (page 42)• Driver Diskette for Linux (page 42)•Wi

Strona 189

SuperTrak EX Series User Manual42Driver Diskette for WindowsIf you have a Windows PC and plan to install your SuperTrak driver from a diskette, follow

Strona 190

Chapter 3: Installing Drivers43Windows VistaNew OS InstallationThe following details the installation of the SuperTrak EX Series RAID Controller drive

Strona 191

SuperTrak EX Series User Manual44Existing SystemAfter installing the SuperTrak EX Series RAID Controller card and rebooting your system, Windows Vista

Strona 192

Chapter 3: Installing Drivers45Windows Server 2003New OS InstallationThe following details the installation of the SuperTrak EX Series RAID Controller

Strona 193

SuperTrak EX Series User Manual46Existing SystemAfter installing the SuperTrak EX Series RAID Controller card and rebooting your system, Windows Serve

Strona 194

Chapter 3: Installing Drivers47Windows XPNew OS InstallationThe following details the installation of the SuperTrak EX Series RAID Controller drivers

Strona 195 - Delete and Recreate

SuperTrak EX Series User ManualviChapter 3: Installing Drivers, cont.Windows Server 2003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 196 - Media Patrol

SuperTrak EX Series User Manual48Existing SystemAfter installing the SuperTrak EX Series RAID Controller card and rebooting your system, Windows XP se

Strona 197 - Transition

Chapter 3: Installing Drivers49Windows 2000New OS InstallationThe following details the installation of the SuperTrak EX Series RAID Controller driver

Strona 198

SuperTrak EX Series User Manual50Existing SystemAfter installing the SuperTrak EX Series RAID Controller card and rebooting your system, Windows 2000

Strona 199 - Manual Transition

Chapter 3: Installing Drivers51Red Hat Linux Enterprise 4.4, 4.5New OS Installation 1. Start the RedHat Linux Installation by booting from the install

Strona 200

SuperTrak EX Series User Manual52SuSE Linux Enterprise 10.1New OS Installation1. Start the SuSE Linux Installation by booting from the install CD. 2.

Strona 201 - When a Physical Drive Fails

53Chapter 4: SuperBuild™ UtilitySuperTrak BIOSThis section explains the information that you can obtain from the SuperTrak BIOS.When the SuperTrak BIO

Strona 202

SuperTrak EX Series User Manual54 Figure 1. SuperTrak BIOS screen If the SuperBuild BIOS detects a Critical logical drive, the BIOS reports the condit

Strona 203 - Rebuild Operation

Chapter 4: SuperBuild™ Utility55If the SuperTrak BIOS detects an Offline logical drive, the BIOS reports the condition and temporarily halts the booti

Strona 204 - • The alarm is silent

SuperTrak EX Series User Manual56Main MenuThe opening screen of the SuperBuild utility is the Main Menu. Figure 4. SuperBuild Main MenuThe Main Menu (

Strona 205 - Chapter 7: Support

Chapter 4: SuperBuild™ Utility57• Miscellaneous – SAS drive LEDs, enclosure management, and buzzer settingsController SelectionThe SuperBuild Configur

Strona 206 - Drive Issues

ContentsviiChapter 4: SuperBuild™ Utility, cont.Logical Drive Management, cont.Initializing a Logical Drive . . . . . . . . . . . . . . . . . . . . .

Strona 207

SuperTrak EX Series User Manual58Controller InformationThe SuperBuild utility displays information about the selected SuperTrak EX controller.1. In th

Strona 208 - Post-Installation

Chapter 4: SuperBuild™ Utility59Physical Drive ManagementPhysical drive management includes these functions:• Viewing Physical Drives (page 59)• Viewi

Strona 209 - Contacting Technical Support

SuperTrak EX Series User Manual603. Highlight Return to Previous Menu and press Enter.Managing Physical Drive ProblemsPhysical drives can develop prob

Strona 210 - The Netherlands

Chapter 4: SuperBuild™ Utility61Disk Array ManagementDisk array management includes these functions:• Viewing Disk Arrays (page 61)• Viewing Disk Arra

Strona 211 - Limited Warranty

SuperTrak EX Series User Manual62Status – OK is normal. Can also show Rebuilding, Degraded, Critical, or Offline.3. Highlight Physical Drives in the D

Strona 212

Chapter 4: SuperBuild™ Utility63Changing Disk Array SettingsTo change the name of a disk array:1. In the Main Menu, highlight Disk Array Management an

Strona 213 - Your Responsibilities

SuperTrak EX Series User Manual64Logical Drive ManagementLogical drive management includes these functions:• Viewing Logical Drives (page 64)• Viewing

Strona 214

Chapter 4: SuperBuild™ Utility65RAID Level – Chosen when the logical drive was created.Stripe Size – Chosen when the logical drive was created.Sector

Strona 215

SuperTrak EX Series User Manual66• Read Cache Policy – Choose from Read Cache, Read Ahead, or No Cache.• Axle – RAID 50 and 60 logical drives only. Ch

Strona 216

Chapter 4: SuperBuild™ Utility67The Initialization begins immediately. If you set Initialization for multiple logical drives, they will be initialized

Strona 217

SuperTrak EX Series User ManualviiiChapter 5: Management with WebPAM PRO, cont.Accessing the Interface, cont.Deleting the Event Frame . . . . . . . .

Strona 218 - (below)

SuperTrak EX Series User Manual68Managing Logical Drive ProblemsThe most common logical drive problems are caused by physical disk drive failure, resu

Strona 219 - Appendix B: Upgrades

Chapter 4: SuperBuild™ Utility69Rebuilding the Logical DriveThe remedial action for a critical logical drive is to rebuild it, meaning the data from t

Strona 220 - Updating WebPAM PRO

SuperTrak EX Series User Manual705. Highlight the Source Sequence Number and press Enter. Then type the ID number of one of the physical drives you no

Strona 221

Chapter 4: SuperBuild™ Utility71BIOS reports the condition and temporarily halts the booting process of the Host PC, so you can access the SuperBuild

Strona 222 - Installing the BBU

SuperTrak EX Series User Manual72RAID 0Because RAID 0 logical drives are not fault-tolerant, there is no way to rebuild the logical drive when a physi

Strona 223

Chapter 4: SuperBuild™ Utility73Spare Drive ManagementSpare drive management includes these functions:• Viewing Spare Drives (page 73)• Viewing Spare

Strona 224

SuperTrak EX Series User Manual74• Big Enough – Same capacity or greater than the largest drive in your arrayTo create a spare drive:1. In the Main Me

Strona 225 - LED activity = Low

Chapter 4: SuperBuild™ Utility754. Optional. If you chose Dedicated in step 3, press the arrow keys to highlight a disk array. Then press the spacebar

Strona 226

SuperTrak EX Series User Manual76Background ActivityThe Background Activity function enables you to monitor background activities are running on the S

Strona 227

Chapter 4: SuperBuild™ Utility77Event LogThe event log tracks events related to the SuperTrak controller and includes the following functions:• Viewin

Strona 228

ContentsixChapter 5: Management with WebPAM PRO, cont.Managing the Subsystem, cont.Viewing the NVRAM Event Log . . . . . . . . . . . . . . . . . . .

Strona 229

SuperTrak EX Series User Manual78• To see all the information about an event, highlight the event and press Enter.Clearing the Event LogsClearing the

Strona 230

Chapter 4: SuperBuild™ Utility79Time SyncThe Time Sync function adds two special features to SuperTrak. These functions include:• Setting the Time Zon

Strona 231

SuperTrak EX Series User Manual80MiscellaneousThe Miscellaneous menu enables three useful functions on SuperTrak:• SAS Ready LEDs (page 80)• SGPIO Bac

Strona 232

Chapter 4: SuperBuild™ Utility81When the buzzer sounds, take the following actions:• Check your disk arrays and logical drives.• Check the Event Log.T

Strona 233

SuperTrak EX Series User Manual82

Strona 234

83Chapter 5: Management with WebPAM PRO• Logging into WebPAM PRO (page 83)• Accessing the Interface (page 86)• Managing Users (page 92)• .Working with

Strona 235

SuperTrak EX Series User Manual84Logging in over the NetworkYou can log into WebPAM PRO from any PC with a network connection to the Host PC (where th

Strona 236

Chapter 5: Management with WebPAM PRO85Login ScreenWhen the opening screen appears:1. Type administrator in the User Name field.2. Type password in th

Strona 237

SuperTrak EX Series User Manual86Accessing the InterfaceWebPAM PRO is browser-based RAID management software with a graphic user interface. Basic user

Strona 238

Chapter 5: Management with WebPAM PRO87There are four major parts to the WebPAM PRO interface:• Header (see page 87)• Tree View (see page 87)• Managem