Strona 1 - User Manual

PROMISE ARRAY MANAGEMENT (PAM) FOR FastTrak S150 SX4 and SX4000 series User Manual Version 4.4

Strona 2

Promise Array Management 6

Strona 3 - Contents

Promise Array Management 96 DHCP Issues Referring to the Figure 84 above, note that it says: Dhcp enabled. . . . . . . . : Yes This means that a DH

Strona 4

97 Appendix D: Technical Support Promise Technical Support provides several support options for Promise users to access information and updates. We

Strona 5 - Chapter 1: Introduction

Promise Array Management 98 Pacific Rim Sales Office E-mail Support [email protected] Fax Technical Support +886 3 578 23 90 Attention: Tech

Strona 6 - How They Work Together

7 Chapter 2: Installation To install Promise Array Management (PAM) is an uncomplicated procedure, once you understand your systems and how you want

Strona 7 - PAM Installation Options

Promise Array Management 8 Router & FirewallLaptop computer+ Monitoring UtilityA networked PC+ Monitoring UtilityCompany LANInternetHome-based P

Strona 8

Chapter 2: Installation 9 Message Server The Message Server installs onto the RAID PC if your installation does not involve a network. If you want

Strona 9

Promise Array Management 10 Network Requirements If you plan to install PAM on a network be sure all the hosts and servers are connected and running

Strona 10 - Promise Array Management

Chapter 2: Installation 11 Figure 5. PAM Setup Opening Screen. 7. Click Next or press Enter to continue. Figure 6. The License Agreement. 8.

Strona 11 - Chapter 2: Installation

Promise Array Management 12 Figure 7. The Setup Type dialog box. 9. In the Setup Type dialog box, make your choice between Complete (Recommended

Strona 12

Chapter 2: Installation 13 Figure 9. Add User Account dialog box. 12. When the Add User Account dialog box appears, you may accept the default n

Strona 13 - Operating System Support

Promise Array Management 14 Figure 10. Install Complete dialog box. 14. When the Install Complete dialog box appears, you have the option to •

Strona 14 - PAM Installation

15 Chapter 3: Initial Setup After you have completed installation, you must setup your PAM Monitoring Utility to work with your RAID. Launch PAM

Strona 15

Promise Array Management ii Copyright © 2003, Promise Technology, Inc. All Rights Reserved. Copyright by Promise Technology, Inc. (Promise Technolog

Strona 16

Promise Array Management 16 Local PAM Log-in Launch Local PAM as described above. When the PAM user interface appears: Figure 12. Logging in to t

Strona 17

Chapter 3: Initial Setup 17 Remote PAM Log-in You must create a RAID Server in order to use Remote PAM. The RAID Server in PAM communicates with the

Strona 18

Promise Array Management 18 Figure 16. List of RAID PCs on the network. 4. Click on the + icon in front of the RAID Server to see the list of ne

Strona 19 - Chapter 3: Initial Setup

Chapter 3: Initial Setup 19 Logout of RAID PC Logout of the RAID Server effectively logs you out of all RAID PCs using that network connection. Yo

Strona 20 - Local PAM Log-out

Promise Array Management 20 PAM User Interface The Monitor window is the user interface for PAM. It appears immediately after login and displays mo

Strona 21 - Remote PAM Log-in

Chapter 3: Initial Setup 21 Create a New User The Administrator is created by default. You must create additional users manually. To create a new Us

Strona 22 - Remote PAM Log-out

Promise Array Management 22 Every User has least one of these three Rights and can change his/her own password. The Administrator can assign more or

Strona 23 - Remote PAM Future Log-ins

Chapter 3: Initial Setup 23 Figure 21. Create Array Settings. 3. The Select the Create Array icon and go to the Create Array Settings in Inform

Strona 24 - PAM User Interface

Promise Array Management 24 5. Click the Create button when you are done. Figure 22. New Array. The new array appears in Tree View. The next ste

Strona 25 - Create a New User

Chapter 3: Initial Setup 25 Setup Email Alert Notification PAM alerts you to the problems and processes happening to your RAID through email and pop

Strona 26 - Create an Array

iii Contents Chapter 1: Introduction... 1 PAM Components

Strona 27

Promise Array Management 26 Figure 25. Email Sender and Recipients. 9. Scroll down to the Email Sender and Recipients box. 10. In the Email ID

Strona 28

Chapter 3: Initial Setup 27 Specify Alert Notification Events PAM can be configured to report a variety of alerts, by email, popup message or both.

Strona 29

Promise Array Management 28 Following is a list of Events and their Severity: Information Events Warning Events Disk S.M.A.R.T. Failed Disk Time O

Strona 30

29 Chapter 4: PAM User Interface This chapter describes PAM’s Graphic User Interface (GUI). You should understand that PAM is software running on to

Strona 31

Promise Array Management 30 Tree View Local PAM The Monitor window is the user interface for PAM. It has three views: Tree View, Object View and Inf

Strona 32

Chapter 4: User Interface 31 Remote PAM Figure 31. An example of a RAID system in Tree View on Remote PAM. Normally, the Tree View is present. To

Strona 33

Promise Array Management 32 Tree View and Component Specific Menus In PAM, like most Windows applications, you can access the various commands and f

Strona 34 - Tree View

Chapter 4: User Interface 33 Information View Information View, like Object View, changes its content depending on which item you select in Tree Vi

Strona 35 - Remote PAM

Promise Array Management 34 Pulldown Menus As indicated above, the left-most item of the Pulldown Menus changes according to which component is sele

Strona 36 - Object View

Chapter 4: User Interface 35 RAID Machine Menu When the RAID Machine is selected, the RAID Machine menu appears. Its functions include: • Login •

Strona 37 - Status Bar

Promise Array Management iv Chapter 5: RAID Monitoring and Maintenance with PAM... 43 Launch PAM...

Strona 38 - Pulldown Menus

Promise Array Management 36 When the Array icon is selected, the Maintenance menu displays Controller functions: • Pause synchronization/rebuild •

Strona 39 - Maintenance Menu

Chapter 4: User Interface 37 Preference Menu The Preference menu allows you to start PAM automatically when your PC boots. Check to enable or unchec

Strona 40 - View Menu

Promise Array Management 38 Toolbar The Toolbar is a series of buttons that are shortcuts to performing specific tasks. You will never see all butto

Strona 41 - Help Menu

Chapter 4: User Interface 39 Popup Menus In addition to the commands in the dropdown menus, there is a corresponding set of commands you can access

Strona 42 - Toolbar

Promise Array Management 40 RAID System Icon The RAID System icon represents the FastTrak SX4000 series and S150 SX4 PCI cards (right). There are

Strona 43 - Popup Menus

Chapter 4: User Interface 41 Array Icon Right-click on the Array icon to access the following commands: • Pause synchronization/rebuild • Continue

Strona 44 - Disk Icon

Promise Array Management 42

Strona 45 - User Icon

43 Chapter 5: RAID Monitoring and Maintenance with PAM This chapter describes using PAM to monitor and manage your RAID system. The chapter is divid

Strona 46

Promise Array Management 44 Local PAM Log-in Launch Local PAM as described above. When the PAM user interface appears: Figure 38. Logging in to t

Strona 47 - Maintenance with PAM

Chapter 5: RAID Monitoring and Maintenance 45 Remote PAM Log-in The RAID Server remains under the My Console icon until deleted. It continues to wor

Strona 48 - Local PAM

1 Chapter 1: Introduction Promise Array Management (PAM) is a utility application designed specifically for monitoring and managing Promise Technolo

Strona 49

Promise Array Management 46 Create a RAID Server The Message Server relays data and commands between the Monitoring Utility on this computer and th

Strona 50 - Create a RAID Server

Chapter 5: RAID Monitoring and Maintenance 47 Delete a RAID Server If the IP address changes for the computer where the Message Server software is i

Strona 51 - Logout of RAID PC

Promise Array Management 48 Future Log-ins The RAID Server remains under the MyConsole icon until deleted. It continues to work as long as the IP ad

Strona 52 - Future Log-ins

Chapter 5: RAID Monitoring and Maintenance 49 Message Server IP Address Change If the IP address changes for the computer where the Message Server

Strona 53

Promise Array Management 50 Manage Users Create a New User The Administrator is created by default. You must create additional users manually. 1. R

Strona 54 - Manage Users

Chapter 5: RAID Monitoring and Maintenance 51 Type in a Username and Password in their respective fields. Check all the appropriate boxes to set acc

Strona 55 - Change User Rights

Promise Array Management 52 Alert Notification PAM alerts you to the problems and processes happening to your RAID through email and popup messages.

Strona 56 - Alert Notification

Chapter 5: RAID Monitoring and Maintenance 53 Figure 48. Email Sender and Recipients. 8. Scroll down to the Email Sender and Recipients box. 9.

Strona 57

Promise Array Management 54 Delete a User from the Recipient List To remove a recipient from the Email Address List, do the following: 1. Click on

Strona 58

Chapter 5: RAID Monitoring and Maintenance 55 Specify Alert Notification Events PAM can be configured to report a variety of alerts, by email, popup

Strona 59

Promise Array Management 2 How They Work Together The Promise Array Management (PAM) utility provides and easy way to set up, monitor, modify and re

Strona 60

Promise Array Management 56 Following is a list of Events and their Severity: Information Events Warning Events Disk S.M.A.R.T. Failed Disk Time Ou

Strona 61 - Controller

Chapter 5: RAID Monitoring and Maintenance 57 Controller The Controller deals with creating new Arrays, reading events from the memory buffer, setti

Strona 62 - System Information

Promise Array Management 58 Controller Options The Controller has system information and settings several important features. Click on the Controlle

Strona 63 - Rebuild Setting

Chapter 5: RAID Monitoring and Maintenance 59 Controller Cache Allows you to toggle between two write modes for the FastTrak's cache: Write Thr

Strona 64 - Inconsistency Error Handling

Promise Array Management 60 PCI Bus Utilization On High setting, FastTrak holds onto the PCI bus longer for data transfers to occur. On Low setting

Strona 65

Chapter 5: RAID Monitoring and Maintenance 61 Arrays Create an Array 1. In Tree View, click the + to the left of the Controller icon to see the C

Strona 66

Promise Array Management 62 Figure 55. Create Array Settings. 3. The Select the Create Array icon and go to the Create Array Settings in Inform

Strona 67

Chapter 5: RAID Monitoring and Maintenance 63 5. Click the Create button when you are done. Figure 56. New Array. The new array appears in Tree

Strona 68 - Scheduled Synchronization

Promise Array Management 64 Synchronize an Array Promise uses the term synchronization to mean an automated process of checking and correcting data

Strona 69 - On Demand Synchronization

Chapter 5: RAID Monitoring and Maintenance 65 On Demand Synchronization In addition to schedule Synchronization, you can direct FastTrak to begin th

Strona 70 - Stop, Pause, Continue

Chapter 1: Introduction 3 PAM Installation Options Following are some examples of ways you can incorporate PAM into your network and RAID systems. R

Strona 71 - Expansion

Promise Array Management 66 Synchronization Settings This feature tells FastTrak how to deal with inconsistencies in mirrored or parity data encount

Strona 72

Chapter 5: RAID Monitoring and Maintenance 67 Expand / Convert an Array Expansion and Conversion are two different operations but they often work to

Strona 73

Promise Array Management 68 Figure 63. Select a disk drive to add to the array. 3. In the Select Free Disk dialog box, click on the icon of any

Strona 74 - Conversion

Chapter 5: RAID Monitoring and Maintenance 69 Figure 65. Verify the Array name and click Finish. 5. In the Finish dialog box, verify the name of

Strona 75

Promise Array Management 70 Conversion Converting changes its RAID Level, and in some cases increases the array capacity, without affecting data ava

Strona 76

Chapter 5: RAID Monitoring and Maintenance 71 To convert an existing array: 1. Click on the Array icon in Tree View. Figure 67. Start Conversi

Strona 77

Promise Array Management 72 Figure 69. Select the new RAID Level. 4. In the Select RAID Mode dialog box, click on the icon of the new RAID level

Strona 78 - Array Critical

Chapter 5: RAID Monitoring and Maintenance 73 Figure 71. Conversion progress. During the Conversion, the array will be available for use but it m

Strona 79

Promise Array Management 74 Array Critical When a disk drive fails on a fault-tolerant array (RAID 1, 0+1 and 5) for any reason, the Array goes Cri

Strona 80 - Automatic Rebuild

Chapter 5: RAID Monitoring and Maintenance 75 In the example above, there are three disk drives attached to the FastTrak controller and all three ar

Strona 81 - Manual Rebuild

Promise Array Management 4 A networked PC+ Monitoring UtilityCompany LANA networked PC+ Monitoring Utility+ Message ServerPC+ FastTrak S150 SX4+ In

Strona 82

Promise Array Management 76 Rebuild an Array To Rebuild to restore redundancy to a RAID 1, 0+1 or 5 after one of its drives has failed. Unlike Sync

Strona 83 - Rebuild Settings

Chapter 5: RAID Monitoring and Maintenance 77 Manual Rebuild After you replace a failed disk drive, the replacement drive must be rebuilt in order t

Strona 84 - Error Handling

Promise Array Management 78 Figure 78. Rebuild Wizard Confirmation window. To confirm the rebuild choice, click Finish. Tree View and Information

Strona 85 - Delete Array

Chapter 5: RAID Monitoring and Maintenance 79 Rebuild Settings Beeper – Right-click on the Controller icon and select Beeper from the popup menu.

Strona 86

Promise Array Management 80 Error Handling This feature deals with a bad sector on a disk drive that the FastTrak Controller encounters during a Re

Strona 87 - Appendix A: RAID Concepts

Chapter 5: RAID Monitoring and Maintenance 81 Array Offline When a disk drive fails on a non-fault-tolerant array (RAID 0) for any reason, the Array

Strona 88 - Striping (RAID 0)

Promise Array Management 82

Strona 89 - Mirroring (RAID 1)

83 Appendix A: RAID Concepts RAID is an acronym that stands for Redundant Array of Independent Disks. It is divided into different numbered Levels.

Strona 90 - Data Stripe

Promise Array Management 84 Striping (RAID 0) Reads and writes sectors of data interleaved between multiple drives. When any disk member fails, it

Strona 91

Appendix A: RAID Concepts 85 Mirroring (RAID 1) Writes duplicate data on to a pair of drives while reads are performed in parallel. RAID 1 is fault

Strona 92 - Distributed Parity

Chapter 1: Introduction 5 PC+ FastTrak S150 SX4+ Internal RAID array+ Monitoring Utility+ Message Server+ Message AgentPC+ FastTrak SX4000 series+

Strona 93 - JBOD - Single Drive

Promise Array Management 86 Striping / Mirroring (RAID 0+1) A combination of RAID 0 and RAID 1 arrays. It can increase performance by reading and wr

Strona 94

Appendix A: RAID Concepts 87 About Dual Data Redundancy One unique (though rarely occurring) feature of RAID 0+1 is dual fault tolerance. In some ca

Strona 95

Promise Array Management 88 Block and Parity Striping (RAID 5) RAID 5 calculates parity in order to achieve redundancy rather than writing a second

Strona 96

Appendix A: RAID Concepts 89 JBOD - Single Drive An alternative to RAID, Just a Bunch of Disks (JBOD) capacity is equal to the sum of all drives in

Strona 97

Promise Array Management 90

Strona 98

91 Appendix B: Partition and Format In order for your Windows to recognize and work with your array, you must partition and format the array. These

Strona 99 - IP Address

Promise Array Management 92 Figure 89. The Disk Management Window and Disk Wizard. 3. Click the Next button to start the Wizard. 4. In the foll

Strona 100 - DHCP Issues

Appendix B: Partition and Format 93 Figure 91. The New Partition Wizard. 6. Click the Next button to start the wizard. 7. In the following win

Strona 101 - Technical Support Services

Promise Array Management 94 Figure 92. The newly formatted array as it appears under Disk Management. When formatting is complete, your array wil

Strona 102

95 Appendix C: Networking Issues IP Address In order for PAM to be configured over a network, you must know the IP (network) address of every compon