Promise Technology VTrack M-Class M500p Instrukcja Obsługi Strona 228

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 227
VTrak M-Class Product Manual
220
Replace Cooling Unit Fan – M300f/i/p and M200f/i/p
The blowers (scroll fans) in the cooling units are replaced as individual parts.
There are two fans in each cooling unit. No tools are required for this procedure.
To replace a fan, do the following:
1. Verify that the Fan LED is amber or red and note whether it is Fan 1 or 2.
See the diagram above.
2. Power down the VTrak.
3. Grasp the cooling unit handle and pull it toward you, as shown above.
4. Pull the cooling unit out of the VTrak enclosure.
Cautions
The Cooling Unit is NOT a hot-swappable device. Power-
down the VTrak before removing it.
If power service has failed, do not remove the cooling unit if
the Controller’s Dirty Cache LED is flashing. See “Unsaved
Data in the Controller Cache” on page 289.
Fan 2 LEDFan 1 LED