Promise Technology SuperTrak SX6000 Instrukcja Użytkownika Strona 13

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 34
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 12
Offline Array Recovery ProceduresSuperTrak SX6000 and UltraTrak, Version 5a
13 of 34
Automatic Rebuild
When automatic rebuilding begins, the disk drive in Channel 4 reappears, confirming
that it is the target of the rebuild. The UltraTrak controller will attempt to rebuild the data
on the failed drive. If it can, the Define Array Menu will display Rebuilding progress and
the target disk drive (above).In this example, the drive on Channel 4 is being rebuilt and
progress is currently at 25 percent. Allow the UltraTrak controller to rebuild the disk
drive.
If this action corrects the problem, return the array to service.
If the array goes CRITICAL again and the controller tries to rebuild the same disk drive,
shut down the computer (SuperTrak) or the UltraTrak and remove the drive for
testing, as described under Remove a Disk Drive for Testing, Testing a Disk Drive,
and Results and Action, above.
If Rebuilding does not start, the array status will remain critical. Recalling which channel
the failed drive was on, you can remove the drive for testing.