Offline Array Recovery ProceduresSuperTrak SX6000 and UltraTrak, Version 5a
28 of 34
Warning
If you leave Initialize Array ON, all of your data will be lost when the new
array is created.
7. Press the arrow keys to move to the Drive Assignments section. Drives are identified
by their Channel ID number. Select the same drives that were used in the array you
are replacing.
8. To select a drive, highlight it with the arrow keys, then press the Spacebar. The
Assignment option appears. Change the option to Y. Repeat this action to select all of
the drives for the array.
9. Press Ctrl-Y to save your inputs when you are done. The Define Array Menu appears
with the new array listed.
SuperBuild Array Utility 1.10 (c) 2001 Promise Technology, Inc.
[ Define Array Menu ]
[ Keys Available ]
Array No RAID Level Total Drv Capacity (MB) Status
Array 1 RAID5 3 61234 Functional
Array 2 RAID0 2 29827 Functional
Array 3 ----- ----- ----- -----
Array 4 ----- ---- ----- -----
Array 5 ----- ---- ----- -----
Array 6 ----- ---- ----- -----
Note: * --Bootable Array
[ ] Up [ ] Down [ESC] Exit [Enter] Select [Space] Change Boot Drive
10. Press Esc to return to the Main Menu. Press Esc again to exit the Utility and return to
your system boot sequence.
When your system completes booting, the new array will appear in your user
interface. All of your data that can be recovered will be present and accessible.