Promise Technology VTrak J610S Instrukcja Obsługi Strona 168

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 167
VTrak E-Class Product Manual
150
Rebuilding Manually
If a physical drive has failed, identify and replace the drive, then rebuild the disk
array as described below:
1. Click the Subsystem icon in Tree View.
2. Click the Disk Arrays icon.
3. Click the Disk Array icon.
If there are multiple disk arrays, choose the icon with the yellow !.
4. From the dropdown menu the Background Activities tab, choose Start
Rebuild.
5. Choose the Source physical drive.
The source drive is a remaining functional physical drive in the disk array.
6. Choose the Target physical drive.
The target drive is the replacement physical drive.
7. Click the Submit button.
The Disk Array Background Activity tab shows the rebuild progress on the
replacement (target) physical drive. Depending the size of the physical disk
involved, this process will take some time.
To view more information, click the Rebuild on PDx link.
To set Rebuild priority, see “Making Background Activity Settings” on page 70.
Running Media Patrol on a Disk Array
Media Patrol checks the magnetic media on physical drives. When it finds the
specified number of bad blocks, it will trigger PDM. See “Making Background
Activity Settings” on page 70 and “Running PDM” on page 71.
You can schedule Media Patrol to run automatically, see “Scheduling an Activity”
on page 72.
To start Media Patrol:
1. Click the Subsystem icon in Tree View.
2. Click the Disk Arrays icon.
3. Click the Disk Array icon.
4. From the dropdown menu the Background Activities tab, choose Start
Media Patrol.
5. Click the Start button.
Przeglądanie stron 167
1 2 ... 163 164 165 166 167 168 169 170 171 172 173 ... 439 440

Komentarze do niniejszej Instrukcji

Brak uwag