Chapter 5: Management with the CLU
127
2. Highlight Enclosure Management and press Enter.
3. Highlight Power Supplies and press Enter.
4. Highlight Locate Power Supply and press Enter.
The LED on the selected power supply blinks for one minute.
Viewing Blower Status
To view the status of the blowers:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight Blowers and press Enter.
The screen displays the status and speed of VTrak’s blowers. There is one
blower in each cooling unit. If blower speed is below the Healthy Threshold, there
is a blower malfunction. See “Replacing a Cooling Unit Fan” on page 181.
Viewing Voltage Sensor Status
To view the status of the voltage sensors:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight Voltage Sensors and press Enter.
If any voltage is outside the Healthy Threshold values, there is a voltage
malfunction in the enclosure. See “Chapter 8: Troubleshooting” on page 213.
Viewing Temperature Sensor Status
To view the status of the temperature sensors:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight Temperature Sensors and press Enter.
If any temperature exceeds the Healthy Threshold value, there is an overheat
condition in the enclosure. See “Setting Temperature Thresholds” on page 127
and “Chapter 8: Troubleshooting” on page 213.
Setting Temperature Thresholds
To change temperature thresholds:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight Enclosure Settings and press Enter.