186
Figure 11. Removing the mounting screws and detaching the connector
7. Lift the battery assembly out of the cooling unit.
8. Place a new battery assembly into the cooling unit.
9. Attach the connector on the circuit board.
10. Install the two screws holding the battery assembly in place to the cooling
unit.
11. Place the top section of the cooling unit onto the bottom section and tighten
the thumbscrews.
12. Carefully slide the cooling unit into the enclosure.
13. Gently press the handle in and upward until it locks.
Figure 12.Replacing the cooling unit into the enclosure.
This completes the battery replacement procedure.
Remove this screw
Remove this screwDetach this connector