VTrak M610p Product Manual
60
Setting SCSI Termination
To set Termination for the VTrak SCSI controller “Out” connectors:
1. Click the Subsystem icon in Tree View.
2. Click the Administrative Tools icon.
3. Click on the SCSI Management icon.
The Channel tab displays SCSI Channel Information:
4. Click on the Channel 1 or the Channel 2 link.
5. From the Termination dropdown menu, select Automatic, ON or OFF.
Automatic means the termination function will set itself automatically.
6. Click the Submit button.
Viewing SCSI Target Information
1. Click the Subsystem icon in Tree View.
2. Click the Administrative Tools icon.
3. Click on the SCSI Management icon.
The Channel tab displays SCSI Channel Information:
4. Click on the Target tab.
The Target tab displays information about the 16 SCSI targets on each of
the two SCSI channels:
• SCSI Port ID – 1 or 2
• Target ID – 0 to 15
• Status – Enabled or Disabled
• Negotiated Transfer Rate – Data Transfer Rate in MB/s
• Bus Width – Narrow or Wide
A value of N/A under Transfer Rate or Bus Width appears when the Target is
disabled. To enable a SCSI Target, see “Enabling SCSI Targets” on
page 59.
Cautions
• Turn off termination only when the VTrak is NOT the last
device in the SCSI chain.
• Internal termination only works on the “Out” SCSI connectors.