Chapter 8: Troubleshooting
225
Event Notification Response
When you select Event Notification, WebPAM PROe sends popup and/or email
messages regarding its status. The messages you see depend on your
notification selection and what is currently happening in the VTrak. See “Setting-
up User Event Subscriptions” on page 54.
The table below cites:
• Reported Events – Events that require you to take action
• Corrective Actions – The action you should take in response to the event
A list of event categories is shown below.
• Battery (page 225)
• Blowers (page 226)
• Cache (page 227)
• Controller (page 227)
• Disk Array (page 227)
• Drive Interface Controller
(page 228)
• Enclosure (page 228)
• Event Log (page 228)
• Host Interface Controller
(page 229)
• Logical Drive (page 229)
• Media Patrol (page 230)
• Online Capacity Expansion
(page 231)
• PDM (page 231)
• Physical Disk (page 232)
• PSU (Power Supply Units)
(page 233)
• PSU Fans (page 234)
• RAID Level Migration (page 234)
• Rebuild (page 235)
• Redundancy Check (page 235)
• Resource (page 236)
• Spare Check (page 236)
• Spare Drives (page 236)
• SMART (page 237)
• Stripe Level Migration (page 237)
• Synchronization (page 237)
• System (VTrak) (page 238)
• Transition (page 238)
• Watermark (page 238)
Reported Event Corrective Action
Battery
Battery temperature is
above the threshold
The battery is too hot. Verify proper airflow around
the through the VTrak. If airflow is OK, replace the
battery. See page 184.
Battery temperature is
normal
Normal.
Battery capacity is below
the threshold
Battery is drained. Run battery reconditioning. See
page 85 or page 128.
Komentarze do niniejszej Instrukcji